  1. Guaiac and immunochemical tests for faecal occult blood in colorectal cancer screening.

    Article - En anglais

    Seven hundred and eighty-six subjects spontaneously referring to our Center performed two guaiac (rehydrated hemoccult II (R.HO), and hemoccult sensa (HO S.)), and two immunochemical (OC Hemodia (Hdia) and and hemeselect (Hsel)) faecal occult blood tests on three consecutive faecal determinations.

    The positivity rates of 3 day R.HO, HO S., Hdia, and Hsel were 4.8%, 5.6%, 8.4% and 11.2% respectively.

    One hundred and thirty-five of the 150 subjects with at least one positive test completed the diagnostic work-up.

    Cancer was detected in three subjects and adenomas in 15.

    Mots-clés Pascal : Tumeur maligne, Côlon, Rectum, Adénome, Dépistage, Diagnostic, Méthode étude, Intestin pathologie, Appareil digestif pathologie, Tumeur bénigne, Homme, Hemoccult

    Mots-clés Pascal anglais : Malignant tumor, Colon, Rectum, Adenoma, Medical screening, Diagnosis, Investigation method, Intestinal disease, Digestive diseases, Benign neoplasm, Human