  1. Determination of contamination of a chemical warfare-proof operating theatre with volatile anaesthetic agents and assessment of anaesthetic gas scavenging systems.

    Article - En anglais

    Three types of anaesthetic waste scavenging systems (active antipollution system, Papworth Block passive system and activated charcoal absorber system) were compared with a nonscavenging control to assess their effectiveness in reducing waste halothane concentrations in a chemical warfare-proof operating theatre.

    All three systems were found to reduce the level of pollution significantly.

    Mots-clés Pascal : Anesthésique général, Composé volatil, Bloc opératoire, Appareil, Décontamination, Hygiène

    Mots-clés Pascal anglais : General anesthetic, Volatile compound, Operating room, Apparatus, Decontamination, Hygiene

    Logo du centre Notice produite par :