logo BDSP

Base documentaire

  1. Rotator-cuff tear of the hip.

    Article - En anglais

    We describe an apparently unreported finding during hip operations : a tear at the insertion of gluteus medius and gluteus minimus.

    This defect may well be known to many surgeons with experience of hip replacement and hemiarthroplasty for fractures of the neck of the femur, but a Medline search has failed to find a previous description.

    We made a prospective study of 50 consecutive patients with fractures of the neck of the femur to quantify the incidence of this condition : 11 (22%) had such a tear.

    Mots-clés Pascal : Fracture, Col fémoral, Association, Rupture tissu, Tendon, Muscle fessier, Diagnostic, Peropératoire, Etude longitudinale, Epidémiologie, Incidence, Homme, Membre inférieur, Hanche, Système ostéoarticulaire pathologie, Traumatisme, Juxtaarticulaire pathologie

    Mots-clés Pascal anglais : Fracture, Femoral neck, Association, Tissue rupture, Tendon, Gluteus muscle, Diagnosis, Intraoperative, Follow up study, Epidemiology, Incidence, Human, Lower limb, Hip, Diseases of the osteoarticular system, Trauma, Juxtaarticular disease