  1. Reduction of extremity dose in the radiopharmacy.

    Article - En anglais

    With the future introduction of legislation originating from ICRP60 in mind, the operating procedures for the radiopharmacy were reviewed, with the intention of reducing extremity radiation dose.

    The radio-pharmacist's index fingertip dose was measured using TLDs.

    The radiopharmacist received a mean dose of 0.7 mSv per 10 GBq of administered activity for the right (non-dominant hand) index finger and 0.2 mSv per 10 GBq for the left (dominant hand) index finger.

    These doses were comparable with other publications.

    The radiopharmacist received the largest part of the radiation dose during the preparation of 99Tcm-MDP.

    During this preparation, the saline was withdrawn into a syringe already containing 99Tcm-eluate, which results in a dose to the fingers.

    The technique was changed so that the saline and 99Tcm-eluate were withdrawn and injected separately into a MDP kit.

    This reduced the right finger radiation dose to 0.4 mSv per 10 GBq, while the left finger radiation dose remained at 0.2 mSv per 10 GBq.

    This shows that radiation doses can be effectively reduced using simple changes in procedure.

    Mots-clés Pascal : Produit radioisotopique, Dose limite, Analyse risque, Radioprotection, Dosimètre thermoluminescent, Technétium, Réglementation, Equipe soignante, Exposition professionnelle

    Mots-clés Pascal anglais : Radiopharmaceuticals, Limit dose, Risk analysis, Radioprotection, Thermoluminescent dosimeter, Technetium, Regulation, Health care staff, Occupational exposure

    Logo du centre Notice produite par :
    Inist-CNRS - Institut de l'Information Scientifique et Technique

    Cote : 97-0408191

    Code Inist : 002B02T. Création : 19/12/1997.