logo BDSP

Base documentaire

  1. Pelvic lysis and polyethylene wear at 5-8 years in an uncemented total hip.

    Article, Communication - En anglais

    Annual meeting of the American Academy of Orthopaedic Surgeons. Orlando, FL (USA), 1995/02.

    The clinical and radiographic results of 160 primary, uncemented porous coated total hip replacements performed at 3 teaching hospitals were reviewed.

    Followup was obtained in 132 of 148 (89%) nondeceased patients.

    The acetabular component is a full hemisphere, fabricated of cobalt chrome with a sintered bead coating and was implanted with screws in all cases.

    A 32 mm cobalt chrome femoral head was used in all cases.

    At 2 to 4 years the incidence of pelvic lysis was 0 and no acetabular revisions had been performed.

    At 5 to 8 years followup, 3 of 132 (2%) femoral stems had been revised, while on the acetabulum side discrete expansile pelvic lytic lesions occurred in 15 cases (11%) with 8 cases (5%) requiring revision.

    Abrasion of the screwhead against the backside of the polyethylene liner was seen in all retrieved cases and may have contributed to the development of the lytic lesions seen.

    Use of this uncemented press fit hemispheric acetabular components, using adjunctive screw fixation resulted in an unacceptably high rate of polyethylene wear and aggressive pelvic lysis.

    While the results on the femoral side were good, the results with this uncemented acetabular system did not represent an improvement over previous cemented or uncemented acetabular components.

    Mots-clés Pascal : Prothèse non cimentée, Total, Hanche, Ostéolyse, Os bassin, Complication, Usure, Biomatériau, Ethylène polymère, Epidémiologie, Incidence, Etude longitudinale, Long terme, Homme, Chirurgie orthopédique, Système ostéoarticulaire pathologie, Arthropathie, Pelvis pathologie

    Mots-clés Pascal anglais : Non cemented prosthesis, Total, Hip, Osteolysis, Pelvis bone, Complication, Wear, Biomaterial, Polyethylene, Epidemiology, Incidence, Follow up study, Long term, Human, Orthopedic surgery, Diseases of the osteoarticular system, Arthropathy, Pelvis pathology

    Logo du centre Notice produite par :
    Inist-CNRS - Institut de l'Information Scientifique et Technique

    Cote : 97-0188279

    Code Inist : 002B25I. Création : 21/05/1997.