  1. Lösemittelimmissionen in einem Schulgebäude nach Einsatz von Bautenschutzmittel.

    Article - En allemand

    Traduction en anglais : Solvent-immissions in a school building after the application of a moisture repellent.

    A wall of a school building was treated with a moisture repellent containing a silicone resin and white spirit.

    In the temporal connection with this a child experienced an exacerbation of its bronchial asthma.

    Some weeks after the second application the users of the rooms complained about unpleasant odor and discomfort.

    As shown by analysis the white spirit containing aliphatic and aromatic hydrocarbons diffused through the 50 cm thick stone wall into the classrooms.

    Due to the considerable concentration of the pollutant a part of the building could not be used any longer.

    In Germany no guideline values exist for white spirit or any mixtures of hydrocarbons in indoor air for non-occupational workplaces.

    For the reopening of the rooms a target value of 300 mug VOC/m3 was set.

    The incident shows that building materials can cause health problems and discomfort even if instructions of application are followed.

    Mots-clés Pascal : Pollution intérieur, Pollution air, Solvant organique, Hydrocarbure, Fongicide, Siloxane polymère, Etablissement scolaire, Toxicité, Recommandation, Concentration maximale admissible, Teneur air ambiant, Enfant, Homme, Allemagne, Europe, White spirit

    Mots-clés Pascal anglais : Indoor pollution, Air pollution, Organic solvent, Hydrocarbon, Fungicide, Siloxane polymer, Educational facility, Toxicity, Recommendation, Maximum permissible concentration, Ambient air concentration, Child, Human, Germany, Europe

    Logo du centre Notice produite par :
    Inist-CNRS - Institut de l'Information Scientifique et Technique

    Cote : 96-0220032

    Code Inist : 002B03M02. Création : 199608.